Data centers, which house critical IT infrastructure, depend on uninterruptible power supply (UPS) systems with lead-acid batteries to maintain continuous operation. These batteries can emit hydrogen gas during charging and discharging, posing a significant explosion risk if the gas accumulates. Even small leaks can create hazardous conditions, especially in confined or poorly ventilated areas. To mitigate this, real-time hydrogen monitoring is vital and mandated by safety regulations like OSHA 1910.1000, NFPA 70, and the International Fire Code (IFC). INTEC’s solution provides continuous hydrogen gas detection, enabling early leak detection and compliance with safety standards while protecting both personnel and equipment from fire and explosion risks.

Lithium-ion batteries used in rack systems are becoming more common in data centers, edge deployments, and modular environments. While lithium-ion batteries are generally safer than older chemistries, thermal runaway events caused by overheating, damage, or internal faults can still release toxic and flammable gases, including: carbon monoxide (CO), hydrogen fluoride (HF), volatile organic compounds (VOCs), and hydrogen (H2).

Energy Storage Systems (ESS) store electrical energy for later use, functioning like large, rechargeable batteries for power grids, buildings, data centers, or industrial facilities. Because ESS units hold megawatts of energy, more cells increase the risk of thermal runaway. ESS fires can escalate quickly and release toxic, corrosive, and explosive gases. Codes and standards such as UL 9540A and NFPA 855 require or recommend gas detection in many installations. Gases to monitor in ESS installations include: hydrogen fluoride (HF), carbon monoxide (CO), volatile organic compounds (VOCs), hydrogen (H2), methane, ethane, and ethylene.

Monitored Gases

Hydrogen (H2)

Hydrogen (H2)

Released during battery charging; highly flammable.
Hydrogen (H2)

Carbon Monoxide (CO)

Generated by backup generators during operation; highly toxic.

Hydrogen (H2)

Refrigerants / A2Ls

Used in cooling systems; leaks can displace oxygen and pose hazards.

Hydrogen Fluoride (HF)

Hydrogen Fluoride (HF)

Used in cooling systems; leaks can displace oxygen and pose hazards.

Gas Detection Systems

Data Centers

DGC6

Multi-Point Digital Gas Detection and Control System

Data Centers

DT6

Digital Gas Transmitter

Data Centers

DC6

Digital Gas Transmitters with Auxiliary
Inputs & Control
 SC2 X-Change Gas Sensor Cartridge

SC2

X-Change Gas Sensor Cartridge

Data Centers

SGC6

Standalone Gas Controller